Analyze different types of water, air and noise quality parameters. Now AECL engaged in the monthly/Quarterly environmental monitoring for many Companies/Industries. The activities cover the stack emission, ambient air, water, noise quality and work place environment monitoring for different parameters.
Parameter Analyzed in AECL Lab
Nature of Sample
Parameters Analyzed
Surface Water
PH, Electrical Conductivity, Chloride, T. Alkalinity, P. Alkalinity, Turbidity, Total Hardness, Dissolve Oxygen, Bio-chemical Oxygen Demand, Chemical Oxygen Demand, Total & fecal Coliform, Total Dissolve Solids, Suspended Solid,
Ground Water
PH, Electrical Conductivity, Chloride, T. Alkalinity, P. Alkalinity, Turbidity, Settleable Solids, Calcium Hardness, Total Hardness, Total Coliform, Arsenic and Iron.
Drinking Water
Arsenic, Iron, Total Coliform, Fecal Coliform and Residual Chlorine.
Ambient Air
Fine Particulate Dust (PM2.5), Respirable Dust Content (PM10), Suspended Particulate Matter (SPM), Oxides of Nitrogen (NXOX) Sulphur Di-Oxide (SO2), Carbon Monoxide(CO), Ozone (O3) and Lead (Pb).
Stack Emission
Suspended Particulate Matter (SPM), Oxides of Nitrogen (NXOX) Sulphur Di-Oxide (SO2), Carbon Monoxide (CO) and Carbon-Di-Oxide (CO2).
Liquid Waste
PH, Electrical Conductivity, Chloride, T.Alkalinity, P.Alkalinity, Turbidity, Dissolve Oxygen, Biochemical Oxygen Demand , Chemical Oxygen Demand, Total Solids , Total Dissolve Solids, Suspended Solid, Settleable Solids, Calcium Hardness, Total Hardness, Nitrate, Sulphate, Phosphate, Nitrite and Oil & Grease.
Indoor Air Quality Monitoring
Fine particulate Matter (PM2.5), Respirable Dust Content (PM10), Suspended Particulate Matter (SPM), Oxides of Nitrogen (NXOX) Sulphur Di-Oxide (SO2), Carbon Monoxide (CO), Carbone di-oxide (CO2), Total Volatile Organic Compound (VOC), Ozone (O2), Humidity & Temperature.
Work Place Light
Intensity of Light Level Assessment.
Automatic Weather Monitoring
Ambient Temperature, Wind Direction, Wind Speed, Relative Humidity, Cloud Cover and Rainfall.
Noise
Equivalent Ambient Noise Level in dB.
Energy Audit
Intensity of Light, Leak Detection, Temperature Loss, Power Factor etc.
AECL has collaborated with Dhaka University’s Chemistry Dept. to assess some parameters which cannot be completed with our existing facilities.
AECL maintains optimum accuracy and sophistication in all aspects of laboratory services such as sample collection, analysis and report writing. We calibrate our laboratory equipment regularly to maintain the accuracy and precision.
Available Equipments in AECL Lab
Description
Quantity
Description
Quantity
Respirable Dust Sampler APM 460
5 Sets
COD Bath
2 Sets
Fine Particulate Dust Sampler
3 Sets
Pocket PH Meter
2 Sets
Portable Stack Sampler
1 Set
TDS Meter
2 Sets
Personal Sampler
1 Set
Conductivity Meter
1 Set
UV Spectrophotometer
1 Set
Noise Level Meter
2 Sets
Digital Balance (4 digit)
1 Set
Lux Meter
1 Set
Digital Balance (5 digit)
1 Set
Ultrasonic Leak Detector
2 Sets
Magnetic Stirrer
1 Set
Power Factor Measuring Device
1 Set
Autoclave
1 Set
Infrared Laser Thermometer
1 Set
Electric Oven
1 Set
COD Reactor
1 Set
Incubator
2 Set
Multi-meter
1 Set
Desiccators
1 Set
Distilled Water Plant
1 Set
Steam Bath
1 Set
Refrigerator
2 Set
VOC Analyzer (Indoor Air)
1 Set.
GPS Meter
1 Set.
Stack Emission Analyzer
3 Set